| Characteristic | Value |
|---|---|
| Power Input | 120 VAC |
| Output (Carbontec Heating Film) | 11.2 W/Ft² |
| Output Per Foot | 20.3 W/Ft |
| Secondary Voltage | 24 Volts AC |
| Primary Circuit Breaker Protection | Building Circuit Breaker |
| Secondary Circuit Breaker Protection | 25 Amps |
| Expected Operating Surface Temperatures | 65°F - 97°F (18°C - 36°C) |
| Min. Bending Radius | 2 Inches (50mm) |
| Material | PET Film with Carbon Fibers and Fillers |
| Primary Conductor/Transformer | 12 AWG to the Mains and/or Controller |
| Secondary Conductor/Transformer | 10 AWG, Max. 30 Feet (10m) in Length |
| Heating Dimension Width | 23 Inches (58.42cm), 21 Inches (53.34cm) Net Heating Width |
| Min. Length | 3 Feet (1 Meter) |
| Max. Length | 12 Feet (4 Meter) |
| Max. Heat Transfer Resistance Value For Flooring Coverings | 1.0 hr x °F x Ft²/BTU (0.15 m²K/W) |
| BTU Output To Output Per Square Foot | 38.21 BTU/hr per Ft² |
| BTU Output To Output Per Linear Foot | 69.2 BTU/hr per Ft |